Sample Record
Owner Lab
- SCST, LLC
DIME Sample ID 2014-01-22-8082210
Project Information
Project Identifiers | Project ID: 8127 DEA: 080N5904 EFIS: 0800000533 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R85.2 |
Award Date | 02/07/2013 |
Closeout Date | 05/11/2015 |
Work Description | CONSTRUCT PC/PS BULB-TEE GIRDER BRIDGE |
Location Description | SAN BERNARDINO COUNTY NEAR ESSEX AT VAN WINKLE WASH BRIDGE |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 01/22/2014 | Sample Unique Key | 8082210 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/23/2014 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Source |
First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Sanchez |
Title of sampler | Field Technician | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | High Grade | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Concrete | The concrete mix design number | SITI2SK |
---|---|---|---|
The truck number from where the sample was collected | 193 | The batch plant ticket number from where the sample was collected | 813444 |
Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
A detailed description of where the material sample was collected | Concrete Truck 193 | Where the material sample would have been placed if not sampled | West Abutment No. 1 - Second Lift |
From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2014-01-22-8082210-1 ASTM C173-10b (Verified)
DIME Test ID: 2014-01-22-8082210-2 ASTM C143-10a (Verified)
DIME Test ID: 2014-01-22-8082210-3 ASTM C1064-08 (Verified)
DIME Test ID: 2014-01-22-8082210-4 ASTM C39-10 (Verified)
DIME Test ID: 2014-01-22-8082210-5 ASTM C39-10 (Verified)
DIME Test ID: 2014-01-22-8082210-6 ASTM C39-10 (Verified)
DIME Test ID: 2014-01-22-8082210-7 ASTM C39-10 (Verified)