Sample Record

Owner Lab

  • SCST, LLC

DIME Sample ID 2014-01-14-8507766

Project Information

Project IdentifiersProject ID: 8127
DEA: 080N5904
EFIS: 0800000533
DIST-CO-RTE-PM08-SBD-40-R85.2
Award Date02/07/2013
Closeout Date05/11/2015
Work DescriptionCONSTRUCT PC/PS BULB-TEE GIRDER BRIDGE
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT VAN WINKLE WASH BRIDGE
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date01/14/2014 Sample Unique Key8507766
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2014
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes5 cylinders From where was the sample collectedSource
First name of sampler or witnessed byJames Last name of sampler or witnessed bySanchez
Title of samplerField Technician Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameHigh Grade Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeConcrete The concrete mix design numberHG534012
The truck number from where the sample was collected174 The batch plant ticket number from where the sample was collected813308
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleNot set
A detailed description of where the material sample was collectedConcrete Truck 174 Where the material sample would have been placed if not sampledBent 3 South Column
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2014-01-14-8507766-1ASTM C173-10b: Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric MethodJames Sanchez, SCST, LLC01/14/2014James Sanchez
Yes
02/10/2014
2014-01-14-8507766-2ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteJames Sanchez, SCST, LLC01/14/2014James Sanchez
Yes
02/10/2014
2014-01-14-8507766-3ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJames Sanchez, SCST, LLC01/14/2014James Sanchez
Yes
02/10/2014
2014-01-14-8507766-4ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNicolas Winters, SCST, LLC01/21/2014Nicolas Winters
Yes
02/10/2014
2014-01-14-8507766-5ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNicolas Winters, SCST, LLC01/28/2014Nicolas Winters
Yes
02/10/2014
2014-01-14-8507766-6ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNicholas Winters, SCST, LLC02/11/2014Nicholas Winters
Yes
02/14/2014

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2014-01-14-8507766-1 ASTM C173-10b (Verified)
DIME Test ID: 2014-01-14-8507766-2 ASTM C143-10a (Verified)
DIME Test ID: 2014-01-14-8507766-3 ASTM C1064-08 (Verified)
DIME Test ID: 2014-01-14-8507766-4 ASTM C39-10 (Verified)
DIME Test ID: 2014-01-14-8507766-5 ASTM C39-10 (Verified)
DIME Test ID: 2014-01-14-8507766-6 ASTM C39-10 (Verified)