Sample Record
Owner Lab
- Trinity Engineering Laboratories, Incorporated - Fresno
DIME Sample ID 2020-07-22-38
Project Information
Project Identifiers | Project ID: 214292 DEA: 060Q9004 EFIS: 0614000047 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-92.2,130.1 |
Award Date | 12/13/2019 |
Closeout Date | 10/29/2020 |
Work Description | REPLACE BRIDGE RAILS. |
Location Description | FRESNO COUNTY NEAR SQUAW VALLEY AT MILL CREEK BRIDGE AND NEAR BOYDEN CAVE AT SOUTH FORK KINGS RIVER BRIDGE |
QA Service Level | 1 (Verified on 08/05/2019) |
Sample Information
Sample Taken Date | 07/22/2020 | Sample Unique Key | 38 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2020 |
Sample type | Quality Control | A brief description of the sample | 3/8 |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Wojdylak |
Title of sampler | QC Technician | Telephone number of sampler | 5592922188 |
Laboratory sample identification | 20-166 Sand | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Outback Materials | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 10-42-0080 | |
Structure name | Mill Creek Bridge |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0005::COALINGA PIT #1 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/8 | The fabricator/manufacturer designation for the sample | Mill Creek Bridge |
The plant number | 106 | A detailed description of where the material sample was collected | Belt Cut |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | 72T1X10 | Lot number | 1 |
Sublot number | 1 | Aggregate Mix Number | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2020-07-22-38-1 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Joshua Guilmette, Trinity Engineering Laboratories, Incorporated - Fresno | 07/22/2020 | Christen Guilmette | No | Info | ||
2020-07-22-38-2 | CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying | Joshua Guilmette, Trinity Engineering Laboratories, Incorporated - Fresno | 07/22/2020 | Christen Guilmette | No | Info | ||
2020-07-22-38-3 | CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness) | Joshua Guilmette, Trinity Engineering Laboratories, Incorporated - Fresno | 07/22/2020 | Christen Guilmette | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-07-22-38-1 CTM 202-November 2011
DIME Test ID: 2020-07-22-38-2 CTM 226-July 2010
DIME Test ID: 2020-07-22-38-3 CTM 227-December 2014