Sample Record

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2020-07-27-18

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214701
DEA: 030F2844
EFIS: 0319000204
DIST-CO-RTE-PM03-SAC-99-7.1/9.4
Award Date05/14/2020
Closeout Date11/27/2023
Work DescriptionConstruct new PCC precast girder bridge over UPRR at McConnell OH between existing SB and NB alignments
Location DescriptionNot set
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date07/27/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2020
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutestwo cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJIM Last name of sampler or witnessed by0000000000
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCollected at jobsite Transportation Laboratory (TL) Number173247
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number545
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0000000000000
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedABUT 2 WALL POUR 2 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-07-27-18-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensPM, CT HQ - Sacramento Concrete Testing Laboratory08/10/2020PM
Yes
08/10/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-07-27-18-1 ASTM C39-17a (Verified)