Sample Record
Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
DIME Sample ID 2020-07-06-3
Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/06/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/06/2020 |
Sample type | Control Sample | A brief description of the sample | Control for Fly Ash |
The quantity of what the sample constitutes | 6 cubes | From where was the sample collected | Source |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM209004 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | GCC Pueblo | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | GCC of America |
---|---|---|---|
Mill | Pueblo Colorado | Type of Cementitious Material | Type II/V Cement |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2020-07-06-3-2 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 07/13/2020 | Spencer Adams | No | Info | ||
2020-07-06-3-3 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 08/03/2020 | Spencer Adams | No | Specimen 3 break was outside allowable range per Section 13 of ASTM C109-16. Correct average compressive strength is 6060 PSI. | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-07-06-3-2 ASTM C109-16a
DIME Test ID: 2020-07-06-3-3 ASTM C109-16a