Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-06-30-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214702
DEA: 030F2864
EFIS: 0320000123
DIST-CO-RTE-PM03-SAC-99-7.92 / 8.4
Award Date06/24/2020
Closeout Date11/28/2023
Work DescriptionRemove and replace Consumnes River and Consumnes River Overflow bridge
Location DescriptionSacramento County
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date06/30/2020 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/01/2020
Sample typeQuality Assurance A brief description of the sampleHRC Couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byYolanda Last name of sampler or witnessed bypulido villegas
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC849204
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC CMC Rebar Intermediate Assembler or FabricatorUnknown
Rebar Size#14 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)73115263 377414 Rebar Heat Number(s)9000558
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-06-30-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020fsaylor
Yes
07/02/2020OK Necking
2020-06-30-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020fsaylor
Yes
07/02/2020OK Necking
2020-06-30-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020fsaylor
Yes
07/02/2020OK Necking
2020-06-30-9-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020fsaylor
Yes
07/02/2020OK Necking
2020-06-30-9-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020fsaylor
Yes
07/02/2020OK Necking
2020-06-30-9-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020fsaylor
Yes
07/02/2020OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-06-30-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-06-30-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-06-30-9-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-06-30-9-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-06-30-9-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-06-30-9-6 CTM 670-December 2013 (Verified)