Sample Record

Owner Lab

  • CT D05 - San Luis Obispo District Laboratory

DIME Sample ID 2020-06-08-34

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215038
DEA: 051J7804
EFIS: 0518000052
DIST-CO-RTE-PM05-SLO-101-61.88/61.88
Award Date05/15/2020
Closeout DateNot set
Work DescriptionSAFETY IMPROVEMENTS
Location DescriptionWELLSONA SAFETY IMPROVEMENTS, SLO 101
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date06/08/2020 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2020
Sample typeInformational A brief description of the sampleNative Soil
The quantity of what the sample constitutesSite Conditions From where was the sample collectedJob Site
First name of sampler or witnessed byJacob Last name of sampler or witnessed byBerven
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePlanet Earth Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedPM 61.7 3 to 5 foot deep
Where the material sample would have been placed if not sampledUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-06-08-34-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDaniel Gingras, CT D05 - San Luis Obispo District Laboratory06/19/2020Daniel Gingras
Yes
06/30/2020
2020-06-08-34-2CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Daniel Gingras, CT D05 - San Luis Obispo District Laboratory06/19/2020Daniel Gingras
Yes
06/30/2020
2020-06-08-34-3CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerDaniel Gingras, CT D05 - San Luis Obispo District Laboratory06/19/2020Daniel Gingras
Yes
06/30/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-06-08-34-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2020-06-08-34-2 CTM 204-June 2010 (Verified)
DIME Test ID: 2020-06-08-34-3 CTM 301-March 2000 (Verified)