Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2013-11-19-8307297
Project Information
Project Identifiers | Project ID: 7826 DEA: 040A1854 EFIS: 0400020652 COOP: 042363 |
---|---|
DIST-CO-RTE-PM | 04-SON-101-7.1/8.1 |
Award Date | 02/12/2013 |
Closeout Date | 01/03/2017 |
Work Description | RECONSTRUCT INTERCHANGE |
Location Description | SONOMA COUNTY IN PETALUMA FROM 0.6 MILE SOUTH TO 0.4 MILE NORTH OF OLD REDWOOD HIGHWAY OVERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 11/19/2013 | Sample Unique Key | 8307297 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/20/2013 |
Sample type | Verification | A brief description of the sample | SCC |
The quantity of what the sample constitutes | 2 concrete cylinders | From where was the sample collected | Source |
First name of sampler or witnessed by | Ricardo | Last name of sampler or witnessed by | Medina |
Title of sampler | QA Inspector | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | KieCon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Girder G-2 no. 6 |
Material Information
Material Type | Concrete | The concrete mix design number | K6090-621SCC |
---|---|---|---|
The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | 52071and52075 |
Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
A detailed description of where the material sample was collected | By formwork at precast plant | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2013-11-19-8307297-1 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Stanley Mak, CT HQ - QASI Bay Area Field Office | 11/27/2013 | Stanley Mak | No | Stopped test when stress is above 8000 psi to avoid machine overload | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2013-11-19-8307297-1 ASTM C39-10