Sample Record
Owner Lab
- CT D02 - Redding Northern Regional Laboratory
DIME Sample ID 2020-04-28-18
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214589 DEA: 020J1604 |
---|---|
DIST-CO-RTE-PM | 02-PLU-284-0.0/8.3 |
Award Date | 02/11/2020 |
Closeout Date | 10/06/2020 |
Work Description | PLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING). |
Location Description | PLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072 |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 04/28/2020 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/29/2020 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (eq. PG 64-22), 23.0 RAP, 1.0 Lime |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jimmy | Last name of sampler or witnessed by | Montana |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78414 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Ward Lake Plant, Litchfield, CA | Transportation Laboratory (TL) Number | 733185 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
JMF Information
Verification ID | JMF3513-2020-141 | Date Created | 06/16/2020 |
---|---|---|---|
JMF Submittal ID | JMF3511-22-2020-214 | JMF Status | Submittal Rejected For Use |
Producer Mix ID | 20-1278.117-0.75HMA | Rejected Date | 06/19/2020 |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-04-28-18-2 AASHTO T209-12 (Verified)
DIME Test ID: 2020-04-28-18-4 AASHTO T275-07r12 (Verified)
DIME Test ID: 2020-04-28-18-5 AASHTO T269-14 (Verified)