Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-05-26-1
Project Information
Project Identifiers | Project ID: 210673 DEA: 042640F4 EFIS: 0400020132 COOP: 042308A3 |
---|---|
DIST-CO-RTE-PM | 04-SON-- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
Sample Taken Date | 05/26/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/26/2020 |
Sample type | Quality Assurance | A brief description of the sample | HRC 500 510 Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | P | Last name of sampler or witnessed by | Latasa |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Pacitic Steel group Nucor HRC | Transportation Laboratory (TL) Number | C744077 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #14 | Coupler Model | HRC 500-510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 73115485 73115263 | Rebar Heat Number(s) | SE17100590 |
Rebar Size 2 | Coupler Unique ID | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2020-05-26-1-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | bewing, CT HQ - Sacramento Structural Materials Testing Laboratory | 05/26/2020 | bewing | No | Info | ||
2020-05-26-1-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 05/26/2020 | fsaylor | No | Service splice | Info | |
2020-05-26-1-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 05/26/2020 | fsaylor | No | Service Splice | Info | |
2020-05-26-1-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory | 05/26/2020 | fsaylor | No | Service splice | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-05-26-1-1 CTM 670-December 2013
DIME Test ID: 2020-05-26-1-2 CTM 670-December 2013
DIME Test ID: 2020-05-26-1-3 CTM 670-December 2013
DIME Test ID: 2020-05-26-1-4 CTM 670-December 2013