Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-04-14-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214449
DEA: 030H3414
EFIS: 0317000152
DIST-CO-RTE-PM03-ED-50-R28.5/R29.1,R31.2
Award Date12/09/2019
Closeout Date07/06/2021
Work DescriptionREPLACE BRIDGE, RESTORE CULVERTS, AND ADD HIGHWAY PLANTING.
Location DescriptionEL DORADO COUNTY NEAR POLLOCK PINES FROM 0.3 MILE WEST TO 0.3 MILE EAST OF RIDGEWAY DRIVE UNDERCROSSING AND AT 0.1 MILE WEST OF SLY PARK ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date04/14/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/15/2020
Sample typeDepartment Acceptance A brief description of the sample#5 A775 Rebar
The quantity of what the sample constitutes12992 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9165170532
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWestern Coatings Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-105-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)443619
Rebar Epoxy Batch Number(s)3CH1936008 Rebar Coating SpecificationASTM A775
Rebar Size (#)5 Rebar Coating ColorGreen
Rebar ManufacturerCascade Rebar CoaterWestern Coating Eugene OR
Rebar Powder ManufacturerValspar Release Number45850
Quality Assurance CodeUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-04-14-6-1ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/16/2020Fred Saylor
Yes
04/16/2020
2020-04-14-6-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/16/2020Fred Saylor
Yes
04/16/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-04-14-6-1 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2020-04-14-6-2 ASTM A775-07b-re14 (Verified)