Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2020-03-26-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/26/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/30/2020
Sample typeStock A brief description of the sample3/4"-10 x 30" x 4" anchor bolts
The quantity of what the sample constitutes1017 From where was the sample collectedManufacturer
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Circle Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-073-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)428917 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationASTM F1554 Gr 55
Bolt Length(s)30" x 4" Nut SpecificationN/A
Washer SpecificationN/A FinishGalvanized
Diameter/Size3/4" Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-03-26-10-1ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020fsaylor
Yes
04/02/2020
2020-03-26-10-2ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020fsaylor
Yes
04/02/2020
2020-03-26-10-3ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-4ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-5ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-6ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-7ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-8ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-9ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020
2020-03-26-10-10ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory04/02/2020Fred Saylor
Yes
04/02/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-03-26-10-1 ASTM A370-15 (Verified)
DIME Test ID: 2020-03-26-10-2 ASTM A370-15 (Verified)
DIME Test ID: 2020-03-26-10-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-03-26-10-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-03-26-10-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-03-26-10-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-03-26-10-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-03-26-10-8 ASTM B499-14 (Verified)
DIME Test ID: 2020-03-26-10-9 ASTM B499-14 (Verified)
DIME Test ID: 2020-03-26-10-10 ASTM B499-14 (Verified)
DIME Test ID: 2020-03-26-10-11 ASTM B499-14 (Verified)
DIME Test ID: 2020-03-26-10-12 ASTM B499-14 (Verified)