Sample Record

Owner Lab

  • CEMEX - Central & Southern California

DIME Sample ID 2020-03-11-19

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/11/2020 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/11/2020
Sample typeAggregate Prequalification Program A brief description of the sample3/8" x #8
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byMarc Last name of sampler or witnessed bySegura
Title of samplerTechnical Services Supervisor Telephone number of sampler(909) 436-8680
Laboratory sample identification Linked DIME Sample ID2020-03-11-18
The fabricator/manufacturer/facility nameLytle Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040::LYTLE CREEK
The fabricator's/manufacturer's product name for the sample3/8 x 8 concrete aggregate The fabricator/manufacturer designation for the sampleUnknown
The plant number4419 A detailed description of where the material sample was collectedStockpile at the Plant
Where the material sample would have been placed if not sampledReady Mix Concrete Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-03-11-19-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesGregory Vinson, CEMEX - Central & Southern California03/26/2020Gregory Vinson
Yes
03/26/2020
2020-03-11-19-2CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Gregory Vinson, CEMEX - Central & Southern California03/26/2020Gregory Vinson
Yes
03/26/2020
2020-03-11-19-3CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateMarc Segura, CEMEX - Central & Southern California04/02/2020Marc Segura
Yes
06/19/2020
2020-03-11-19-4CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing MachineMarc Segura, CEMEX - Central & Southern California04/02/2020Marc Segura
Yes
06/19/2020
2020-03-11-19-5CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse AggregateMarc Segura, CEMEX - Central & Southern California04/02/2020Marc Segura
Yes
06/19/2020
2020-03-11-19-6CTM 229-June 2011: Method of Test for Durability IndexMarc Segura, CEMEX - Central & Southern California04/02/2020Marc Segura
Yes
06/19/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-03-11-19-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2020-03-11-19-2 CTM 227-December 2014 (Verified)
DIME Test ID: 2020-03-11-19-3 CTM 214-August 2010 (Verified)
DIME Test ID: 2020-03-11-19-4 CTM 211-May 2010 (Verified)
DIME Test ID: 2020-03-11-19-5 CTM 206-October 2011 (Verified)
DIME Test ID: 2020-03-11-19-6 CTM 229-June 2011 (Verified)