Sample Record

Owner Lab

  • CT D05 - San Luis Obispo District Laboratory

DIME Sample ID 2020-02-24-27

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213835
DEA: 051F7404
EFIS: 0514000049
DIST-CO-RTE-PM05-MON-101-R28.0/R30.6
Award Date04/03/2019
Closeout Date08/23/2021
Work DescriptionPLACE CONTINUOUSLY REINFORCED CONCRETE PAVEMENT ON EXISTING ROADWAY.
Location DescriptionMONTEREY COUNTY NEAR SAN LUCAS FROM 0.1 MILE SOUTH OF PARIS VALLEY ROAD OVERCROSSING TO RANCHO UNDERCROSSING
QA Service Level1 (Verified on 02/18/2019)

Sample Information

Sample Taken Date02/24/2020 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/26/2020
Sample typeDepartment Acceptance A brief description of the sampleClass I ASB from Crusher
The quantity of what the sample constitutes2 bags From where was the sample collectedJob Site
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWood
Title of samplerField Technician Telephone number of sampler
Laboratory sample identificationD5 20-C-003 Linked DIME Sample ID
The fabricator/manufacturer/facility namePapich Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedJobsite Crusher
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-02-24-27-1CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerDaniel Gingras, CT D05 - San Luis Obispo District Laboratory02/28/2020Daniel Gingras
Yes
02/28/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-02-24-27-1 CTM 301-March 2000 (Verified)