Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2020-02-13-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214159
DEA: 081J4104
EFIS: 0818000040
DIST-CO-RTE-PM08-SBD-71-R4.7
Award Date06/18/2019
Closeout Date08/09/2021
Work DescriptionWIDEN RAMP & RIGHT TURN LANE WITH HMA AND MODIFY ELECTRICAL SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY IN CHINO HILLS AT SOQUEL CANYON PARKWAY SOUTHBOUND EXIT RAMP
QA Service Level1 (Verified on 12/02/2019)

Sample Information

Sample Taken Date02/13/2020 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/18/2020
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutes13 CY From where was the sample collectedJob Site
First name of sampler or witnessed bySaad Last name of sampler or witnessed byArabi
Title of samplerTE Telephone number of sampler
Laboratory sample identification1008-66 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons Transportation Laboratory (TL) Number200066
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected5082194 The batch plant ticket number from where the sample was collectedVARIOUS
Concrete batch plantROBERTSONS The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedHOPPER Where the material sample would have been placed if not sampledRet Wall Stem
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-02-13-12-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory02/18/2020Matthew Clayton
Yes
02/18/2020
2020-02-13-12-2ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory02/24/2020Matthew Clayton
Yes
02/24/2020
2020-02-13-12-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory03/12/2020Matthew Clayton
Yes
03/12/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-02-13-12-1 ASTM C39-17a (Verified)
DIME Test ID: 2020-02-13-12-2 ASTM C39-10 (Verified)
DIME Test ID: 2020-02-13-12-3 ASTM C39-17a (Verified)