Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-01-31-3

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date01/31/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/07/2020
Sample typeQuality Assurance A brief description of the sample# 5 1'-2" Ø Hoops
The quantity of what the sample constitutes(40) # 5 1'-2" Ø Hoops From where was the sample collectedFabricator
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerInspector Telephone number of sampler951-500-0685
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-024-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)3500009960
Hoop Manufacturer Lot Number(s)Lot 33 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop1'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucur
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-01-31-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/06/2020bewing
Yes
02/06/2020Ok Necking
2020-01-31-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/06/2020bewing
Yes
02/06/2020Ok Necking
2020-01-31-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/06/2020bewing
Yes
02/06/2020Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-01-31-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-01-31-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-01-31-3-3 CTM 670-December 2013 (Verified)