Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2019-11-25-5
Project Information
Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 11/25/2019 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/27/2019 |
Sample type | Department Acceptance | A brief description of the sample | Schnell Resistance Flash Welder |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | QA Inspector | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-168-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 9000507 |
Hoop Manufacturer Lot Number(s) | NA | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 9 |
Diameter of Hoop | 4'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel CA |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2019-11-25-5-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | bewing, CT HQ - Sacramento Structural Materials Testing Laboratory | 12/13/2019 | bewing | No | Broke at Weld | Info | |
2019-11-25-5-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | bewing, CT HQ - Sacramento Structural Materials Testing Laboratory | 12/13/2019 | bewing | No | Broke at Weld | Info | |
2019-11-25-5-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | bewing, CT HQ - Sacramento Structural Materials Testing Laboratory | 12/13/2019 | bewing | No | Broke at Weld | Info | |
2019-11-25-5-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | bewing, CT HQ - Sacramento Structural Materials Testing Laboratory | 12/13/2019 | bewing | No | Broke at Weld | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-11-25-5-1 CTM 670-December 2013
DIME Test ID: 2019-11-25-5-2 CTM 670-December 2013
DIME Test ID: 2019-11-25-5-3 CTM 670-December 2013
DIME Test ID: 2019-11-25-5-4 CTM 670-December 2013