Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-11-13-37

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Award Date11/07/2016
Closeout DateNot set
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
QA Service Level1 (Verified on 09/10/2015)

Sample Information

Sample Taken Date11/13/2019 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/20/2019
Sample typeQuality Assurance A brief description of the sampleHeaded Rebar
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byDanny Last name of sampler or witnessed byReyes
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)4090965 Head Manufacturer Lot Number(s)1, 5, 8
Rebar Size5 Headed Bar Model NameHRC 120
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeCircular Rebar ManufacturerCMC
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-11-13-37-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking
2019-11-13-37-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Head Popped Off
2019-11-13-37-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Head Popped Off
2019-11-13-37-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking
2019-11-13-37-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking
2019-11-13-37-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking
2019-11-13-37-7ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking
2019-11-13-37-8ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Head Popped Off
2019-11-13-37-10ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking
2019-11-13-37-11ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/21/2019bewing
Yes
11/26/2019Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-11-13-37-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-6 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-7 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-8 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-10 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-11 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-11-13-37-12 ASTM A970-15e1 (Verified)