Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2019-10-31-4
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213745 DEA: 080Q1204 EFIS: 0800020125 |
---|---|
DIST-CO-RTE-PM | 08-SBD-18-99.5-100.9 |
Award Date | 02/19/2019 |
Closeout Date | 03/24/2020 |
Work Description | WIDEN ROADBED AND CONSTRUCT RAISED CURB MEDIAN |
Location Description | SAN BERNARDINO COUNTY FROM COBALT ROAD TO ROUTE 395 |
QA Service Level | 1 (Verified on 04/02/2019) |
Sample Information
Sample Taken Date | 10/31/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2019 |
Sample type | Verification | A brief description of the sample | 3/8 HMA-A-SP R15 |
The quantity of what the sample constitutes | PSUE 7 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Blue Diamond Materials Victorville | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0671A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Agcon-Oro Grande, Cemex-White Mountain | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0046, 91-36-0106 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/8 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | 300153-WM |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at Blue Diamond Victorville Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-10-31-4-1 AASHTO T27-14 (Verified)
DIME Test ID: 2019-10-31-4-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-10-31-4-3 AASHTO T85-13 (Verified)
DIME Test ID: 2019-10-31-4-4 AASHTO T84-14 (Verified)
DIME Test ID: 2019-10-31-4-5 AASHTO T96-02r10 (Verified)
DIME Test ID: 2019-10-31-4-6 AASHTO T176-08 (Verified)
DIME Test ID: 2019-10-31-4-7 ASTM D4791-10 (Verified)
DIME Test ID: 2019-10-31-4-8 AASHTO T304-11 (Verified)
DIME Test ID: 2019-10-31-4-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2019-10-31-4-10 CTM 202-November 2011 (Verified)