Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-09-20-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213856
DEA: 112888U4
EFIS: 1118000199
DIST-CO-RTE-PM11-SD-11,125,905-Various
Award Date05/09/2019
Closeout Date09/14/2023
Work DescriptionCONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date09/20/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/23/2019
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes8 From where was the sample collectedManufacturer
First name of sampler or witnessed byTuam Last name of sampler or witnessed byTran
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Steel
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size14 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)74113607, 73112054, 74112219, 62144586 Rebar Heat Number(s)033695
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-09-20-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/23/2019bewing
Yes
09/25/2019Bar Broke, Ok Necking
2019-09-20-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/23/2019bewing
Yes
09/25/2019Bar Broke, Ok Necking
2019-09-20-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/23/2019bewing
Yes
09/25/2019Bar Broke, Ok Necking
2019-09-20-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/23/2019bewing
Yes
09/25/2019Bar Broke, Ok Necking
2019-09-20-2-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/23/2019bewing
Yes
09/25/2019Bar Broke, Ok Necking
2019-09-20-2-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/23/2019bewing
Yes
09/25/2019Bar Broke, Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-09-20-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-20-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-20-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-20-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-20-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-20-2-6 CTM 670-December 2013 (Verified)