Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2019-09-06-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213750
DEA: 120K0224
EFIS: 1214000097
DIST-CO-RTE-PM12-ORA-5-14.5/17.1
Award Date03/05/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/15/2019)

Sample Information

Sample Taken Date09/06/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/06/2019
Sample typeQuality Assurance A brief description of the sample#7 x 5'-0" Dia Hoops
The quantity of what the sample constitutes4 Lots (582 pcs) From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler5599740870
Laboratory sample identification Linked DIME Sample ID2019-09-06-1
The fabricator/manufacturer/facility nameTNT Rebar Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-056-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateService Rebar Heat Number(s)9000984
Hoop Manufacturer Lot Number(s)lot 1-4 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop5'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel California
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-09-06-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2019fsaylor
Yes
09/13/2019OK Necking
2019-09-06-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2019fsaylor
Yes
09/13/2019OK Necking
2019-09-06-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2019fsaylor
Yes
09/13/2019OK Necking
2019-09-06-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2019fsaylor
Yes
09/13/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-09-06-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-06-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-06-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-09-06-5-4 CTM 670-December 2013 (Verified)