Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-08-15-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213846
DEA: 041J5614
EFIS: 0419000117
DIST-CO-RTE-PM04-SM-101-0.0/6.7
Award Date12/21/2018
Closeout Date09/01/2022
Work DescriptionBarrier modifications, overhead signs, freeway lighting and electronic toll system components
Location DescriptionSANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND REDWOOD CITY FROM 0.3 MILE NORTH OF SAN ANTONIO ROAD TO WHIPPLE AVENUE OVERCROSSING
QA Service Level1 (Verified on 12/27/2018)

Sample Information

Sample Taken Date08/15/2019 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/16/2019
Sample typeQuality Assurance A brief description of the sampleDouble Barrel Zap Screwlok
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBarsplice, Nucor Transportation Laboratory (TL) NumberC835652
Inspector Lot Number from the Transportation Laboratory (TL) FormB907819 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelDouble Barrel Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)9003 Rebar Heat Number(s)3500005739
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-08-15-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/2019fsaylor
Yes
08/19/2019Service Splice
2019-08-15-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/2019fsaylor
Yes
08/19/2019Service Splice
2019-08-15-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/2019fsaylor
Yes
08/19/2019Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-15-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-15-7-2 CTM 670-December 2013 (Verified)