Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2019-08-07-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212743
DEA: 030H26U4
EFIS: 0317000247
DIST-CO-RTE-PM03-PLA-65-R5.0/R6.6
Award Date02/14/2018
Closeout Date10/21/2022
Work DescriptionNORTHBOUND WIDENING AND RAMP IMPROVEMENTS.
Location DescriptionPLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 12/18/2017)

Sample Information

Sample Taken Date08/07/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/12/2019
Sample typeQuality Assurance A brief description of the sample#5 T-Head bars
The quantity of what the sample constitutes2 Lots From where was the sample collectedFabricator
First name of sampler or witnessed byHitesh Last name of sampler or witnessed byPatel
Title of samplerQuality Assurance Inspector Telephone number of sampler9168691602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL131-181-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4088163 Head Manufacturer Lot Number(s)B1128831
Rebar Size5 Headed Bar Model NameHRC 120
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerCMC Steel Arizona
Head ManufacturerUnknown Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-08-07-4-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2019Brian
Yes
08/14/2019Bar Broke; OK Necking
2019-08-07-4-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2019Brian
Yes
08/14/2019Bar Broke; OK Necking
2019-08-07-4-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2019Brian
Yes
08/14/2019Bar Broke; OK Necking
2019-08-07-4-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2019Brian
Yes
08/14/2019Bar Broke; OK Necking
2019-08-07-4-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2019Brian
Yes
08/14/2019Bar Broke; OK Necking
2019-08-07-4-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2019Brian
Yes
08/14/2019Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-07-4-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-08-07-4-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-08-07-4-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-08-07-4-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-08-07-4-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2019-08-07-4-6 ASTM A970-15e1 (Verified)