Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-06-20-17

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213852
DEA: 034F6004
EFIS: 0314000228
DIST-CO-RTE-PM03-NEV-80-1.2/R9.4
Award Date03/11/2019
Closeout Date05/26/2022
Work DescriptionREMOVE METAL BEAM GUARD RAIL AND REPLACE WITH CONCRETE BARRIER
Location DescriptionNEVADA COUNTY IN AND NEAR TRUCKEE AT VARIOUS LOCATIONS FROM 1.3 MILES WEST OF SODA SPRINGS OVERCROSSING TO 0.3 MILE EAST OF DONNER LAKE UNDERCROSSING
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date06/20/2019 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/24/2019
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated Rebar
The quantity of what the sample constitutes22 From where was the sample collectedManufacturer
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC741538 C741539 C741540 C741541 C741542 C7415
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-031-19 B373-027-19 B373-030-19 B373-0 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)4085737 4085738 4086739 4086945 4086970 4086971 4086999 4087396 4078132
Rebar Epoxy Batch Number(s) Rebar Coating SpecificationASTM A775
Rebar Size (#)#4 #5 Rebar Coating ColorGreen
Rebar ManufacturerCMC Rebar Rebar CoaterCMC Brighton
Rebar Powder ManufacturerUnknown Release NumberUnknown
Quality Assurance CodeUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-06-20-17-1ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT# 4086999
2019-06-20-17-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086999
2019-06-20-17-3ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086739
2019-06-20-17-4ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086739
2019-06-20-17-5ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086971
2019-06-20-17-6ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086971
2019-06-20-17-7ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086970
2019-06-20-17-8ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4086970
2019-06-20-17-9ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4087396
2019-06-20-17-10ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/2019Steven Paine
Yes
06/27/2019HT#4087396

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-06-20-17-1 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-2 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-3 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-4 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-5 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-6 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-7 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-8 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-9 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-10 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-11 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-12 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-13 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-14 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-15 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-16 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-17 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2019-06-20-17-18 ASTM A775-07b-re14 (Verified)