Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-05-20-1

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date05/20/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/20/2019
Sample typeQuality Assurance A brief description of the sampleCoupler Test
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byjomara Last name of sampler or witnessed byjomara
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namejomara fabricator Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar Manufacturerjomara rebar manufacturer
Coupler Manufacturerjomara coupler manufacture Intermediate Assembler or FabricatorUnknown
Rebar Size9 Coupler Modeljomara coupler model
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)1 Rebar Heat Number(s)heat no 1
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-05-20-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/20/2019bewing
No
bar broke ok, necking Info
2019-05-20-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/20/2019bewing
No
bar broke necking Info
2019-05-20-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/20/2019bewing
No
Bar Broke, Ok Necking Info
2019-05-20-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/20/2019bewing
No
bar broke, necking ok Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-05-20-1-1 CTM 670-December 2013
DIME Test ID: 2019-05-20-1-2 CTM 670-December 2013
DIME Test ID: 2019-05-20-1-3 CTM 670-December 2013
DIME Test ID: 2019-05-20-1-4 CTM 670-December 2013