Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-05-08-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212245
DEA: 024F8604
EFIS: 0213000043
DIST-CO-RTE-PM02-TRI-36-26.7/27.1
Award Date11/02/2018
Closeout Date05/23/2022
Work DescriptionROADWAY REALIGNMENT AND NEW BRIDGE CONSTRUCTION
Location DescriptionTRINITY COUNTY ABOUT 9 MILES EAST OF FOREST GLEN FROM 0.6 MILE WEST TO 0.1 MILE WEST OF ROUTE 3
QA Service Level1 (Verified on 03/21/2017)

Sample Information

Sample Taken Date05/08/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/09/2019
Sample typeRetest A brief description of the sampleFlash Welded Rebar Hoops No. 6
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of samplerAssociate Steel Inspector Telephone number of sampler(510) 385-5910
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC741532
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-017-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateService Rebar Heat Number(s)3500003576
Hoop Manufacturer Lot Number(s)350000357620 Material Standard CodeASTM A615
Material Grade60 Rebar Size6
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-05-08-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/09/2019Brian
Yes
05/16/2019Bar Broke; OK Necking
2019-05-08-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/09/2019Brian
Yes
05/16/2019Bar Broke at Weld
2019-05-08-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/09/2019Brian
Yes
05/16/2019Bar Broke; OK Necking
2019-05-08-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/09/2019Brian
Yes
05/16/2019Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-05-08-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-05-08-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-05-08-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-05-08-3-4 CTM 670-December 2013 (Verified)