Sample Record

Owner Lab

  • CT - Southern Regional Laboratory

DIME Sample ID 2019-04-16-22

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212872
DEA: 07302204
EFIS: 0713000481
DIST-CO-RTE-PM07-VEN-126-0.0/R13.6
Award Date01/24/2018
Closeout DateNot set
Work DescriptionPLACE HOT MIX ASPHALT AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY IN VENTURA AND SANTA PAULA FROM ROUTE 126/101 SEPARATION TO HAUN CREEK BRIDGE
QA Service Level1 (Verified on 04/27/2020)

Sample Information

Sample Taken Date04/16/2019 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/22/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesPSE 8 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byJay Last name of sampler or witnessed byOlsen
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identification0242G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Sun Valley Transportation Laboratory (TL) Number002802
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample226108 SVA3 SJR
The plant number3 A detailed description of where the material sample was collectedManufacturer
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID

Submitted Tests

DIME Test IDTest MethodTester NameTesting LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-04-16-22-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Larry DiazCT - Southern Regional Laboratory04/23/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-2AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish JainCT - Southern Regional Laboratory04/26/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Larry DiazCT - Southern Regional Laboratory04/24/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-4AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Danilo FerrerCT - Southern Regional Laboratory04/24/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-5AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Larry DiazCT - Southern Regional Laboratory04/25/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-6AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Husni AnkirCT - Southern Regional Laboratory04/24/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-7ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Satish JainCT - Southern Regional Laboratory04/26/2019Michael Magana
Yes
05/07/2019
2019-04-16-22-8AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Satish JainCT - Southern Regional Laboratory04/26/2019Michael Magana
Yes