Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-03-27-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212304
DEA: 021C7504
EFIS: 0200000080
DIST-CO-RTE-PM02-PLU-70-14.9
Award Date11/30/2017
Closeout Date11/24/2021
Work DescriptionCONCRETE BRIDGE, RETAINING WALLS, HMA, DRAINAGE AND GUARDRAIL.
Location DescriptionPLUMAS COUNTY NEAR BELDEN AT YELLOW CREEK BRIDGE 09-0008
QA Service Level1 (Verified on 04/02/2018)

Sample Information

Sample Taken Date03/27/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/27/2019
Sample typeQuality Assurance A brief description of the sampleGriptwist Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byBryan Last name of sampler or witnessed byKEENE
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBarSplice CMC Rebar Transportation Laboratory (TL) NumberC571976
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size11 Coupler ModelGriptwist Couplers
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A71480, A165149 Rebar Heat Number(s)4080596
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-03-27-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/28/2019Brian
Yes
04/04/2019Service Splice
2019-03-27-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/28/2019Brian
Yes
04/04/2019Service Splice
2019-03-27-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/28/2019Brian
Yes
04/04/2019Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-03-27-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-03-27-2-2 CTM 670-December 2013 (Verified)