Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2019-03-11-8

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/11/2019 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/11/2019
Sample typeControl Sample A brief description of the sampleControl for Fly Ash
The quantity of what the sample constitutes6 cubes From where was the sample collectedOther
First name of sampler or witnessed byBen Last name of sampler or witnessed byLenz
Title of sampler Telephone number of sampler
Laboratory sample identificationCM199002 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCement Lab Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandNational
MillLebec Type of Cementitious MaterialType II/V Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-03-11-8-2ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Ben Lenz, CT HQ - Sacramento Cement Testing Laboratory03/18/2019Spencer Adams
No
7 day test Info
2019-03-11-8-3ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Ben Lenz, CT HQ - Sacramento Cement Testing Laboratory04/08/2019Spencer Adams
No
28 day test -- Specimen 1 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109 Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-03-11-8-2 ASTM C109-16a
DIME Test ID: 2019-03-11-8-3 ASTM C109-16a