Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2019-02-18-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date02/18/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/19/2019
Sample typeQuality Assurance A brief description of the sampleLean Concrete Base
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of samplerTET Telephone number of sampler
Laboratory sample identification976-218 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKiewit Plant Transportation Laboratory (TL) Number1-2-18-19
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierLB18 0031 7day break
Structure nameLB18 0031 7day break

Material Information

Material TypeConcrete The concrete mix design numberLB18-0031
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected13668
Concrete batch plantKiwiet The fabricator/manufacturer designation for the sampleLB18 0031 7day break
A detailed description of where the material sample was collectedKiewit Plant WB 58 Entrance on ramp, Line R-1 Where the material sample would have been placed if not sampled40 cu yd
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-02-18-3-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMM, CT D08 - Fontana Southern Regional Laboratory02/25/2019Minh Pham
Yes
03/04/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-02-18-3-1 ASTM C39-17a (Verified)