Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-10-30-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211778
DEA: 04235654
EFIS: 0400000680
DIST-CO-RTE-PM04-SM-101,114-1.3/2.5,5.0/5.3
Award Date02/10/2017
Closeout Date01/08/2020
Work DescriptionRECONSTRUCT INTERCHANGE
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATIONS ON ROUTE 101 FROM 0.4 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.6 MILE SOUTH OF HENDERSON UNDERPASS AND ON ROUTE 114 FROM WILLOW ROAD SEPARATION TO NEWBRIDGE STREET
QA Service Level1 (Verified on 10/24/2016)

Sample Information

Sample Taken Date10/30/2018 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/31/2019
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byOanh Last name of sampler or witnessed byBui
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC714520
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau, Cascade
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size14 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)75069594, 74106235 Rebar Heat Number(s)6502759302, 201218
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-10-30-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/01/2019Brian
Yes
02/11/2019necking okay
2018-10-30-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/01/2019Brian
Yes
02/11/2019necking okay
2018-10-30-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/01/2019Brian
Yes
02/11/2019necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-10-30-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-30-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-30-9-3 CTM 670-December 2013 (Verified)