Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-10-17-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210837
DEA: 080J0804
EFIS: 0800000283
COOP: 081625
DIST-CO-RTE-PM08-RIV-15-34.7/51.6
Award Date04/17/2017
Closeout DateNot set
Work Description(Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location DescriptionRiverside County and SBD-15-0.0/1.3
QA Service Level1 (Verified on 05/08/2017)

Sample Information

Sample Taken Date10/17/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/22/2018
Sample typeQuality Assurance A brief description of the sample Resistance Butt Welded Hoops
The quantity of what the sample constitutes1281 each From where was the sample collectedFabricator
First name of sampler or witnessed byGary Last name of sampler or witnessed byMaComb
Title of samplerASI Telephone number of sampler5624498001
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormL10-068-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65030869
Hoop Manufacturer Lot Number(s)1, 4, 7 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-10-17-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke; OK Necking
2018-10-17-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke; OK Necking
2018-10-17-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke Heat Affect Zone; NO Necking
2018-10-17-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke in Heat Affected Zone; ON Necking
2018-10-17-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke in Heat Affected Zone; ON Necking
2018-10-17-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke; OK Necking
2018-10-17-3-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke in Heat Affected Zone; OK Necking
2018-10-17-3-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke; OK Necking
2018-10-17-3-9CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke; OK Necking
2018-10-17-3-10CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2018Fred
Yes
11/01/2018Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-10-17-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-10-17-3-11 CTM 670-December 2013 (Verified)