Owner Labs

  • CT SC - 3672 - Fairfield
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-08-13-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213153
DEA: 044S7804
EFIS: 0400020145
DIST-CO-RTE-PM04-MRN-1-24.7
Award Date04/26/2018
Closeout Date10/17/2019
Work DescriptionREPLACE EXISTING CULVERTS WITH 36' REINFORCED CONCRETE SLAB BRIDGE.
Location DescriptionMARIN COUNTY NEAR OLEMA AT 1.8 MILES SOUTH OF SIR FRANCIS DRAKE BOULEVARD
QA Service Level1 (Verified on 06/12/2018)

Sample Information

Sample Taken Date08/13/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/15/2018
Sample typeQuality Assurance A brief description of the samplecoupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJanine Last name of sampler or witnessed byMarr
Title of samplerSR Telephone number of sampler510-385-6764
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerBartec
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorHarris Rebar
Rebar Size5 Coupler Model5
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)DL13101642 Rebar Heat Number(s)DL13101642
Rebar Size 2 5 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-08-13-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2018Brian
Yes
08/24/2018Service Splice
2018-08-13-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2018Brian
Yes
08/24/2018Service Splice
2018-08-13-6-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2018Brian
Yes
08/24/2018Service Splice
2018-08-13-6-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2018Brian
Yes
08/24/2018Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-08-13-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-13-6-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-13-6-5 CTM 670-December 2013 (Verified)