Sample Record

Owner Labs

  • CT HQ - Sacramento Materials Management Branch Field Office
  • CT HQ - Sacramento Aggregate Testing Laboratory

DIME Sample ID 2018-07-06-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Award Date02/03/2016
Closeout Date10/21/2020
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
QA Service Level1 (Verified on 09/23/2015)

Sample Information

Sample Taken Date07/06/2018 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2018
Sample typePer Request A brief description of the sampleRC sand
The quantity of what the sample constitutes1 5gal bucket From where was the sample collectedSource
First name of sampler or witnessed byRedding Concrete Last name of sampler or witnessed bynot provided
Title of samplernot provided Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameredding concrete Transportation Laboratory (TL) Numberc340592
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)not provided
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedredding concrete
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-07-06-5-1ASTM C128-12: Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine AggregateBang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory07/19/2018Bang Nguyen
Yes
07/19/2018
2018-07-06-5-2ASTM C128-12: Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine AggregateBang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory07/19/2018Bang Nguyen
Yes
07/19/2018
2018-07-06-5-3ASTM C128-12: Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine AggregateBang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory07/19/2018Bang Nguyen
Yes
07/19/2018

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-07-06-5-1 ASTM C128-12 (Verified)
DIME Test ID: 2018-07-06-5-2 ASTM C128-12 (Verified)
DIME Test ID: 2018-07-06-5-3 ASTM C128-12 (Verified)