Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2018-07-18-11

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/18/2018 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/18/2018
Sample typeAnnual Source Testing A brief description of the sampleType II/V
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationCM185833 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCal Portland Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandCal Portland
MillOro Grande Type of Cementitious MaterialType II/V Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-07-18-11-2ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)SD, CT HQ - Sacramento Cement Testing Laboratory08/10/2018
Yes
01/25/20193 Day Break
2018-07-18-11-3ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)SD, CT HQ - Sacramento Cement Testing Laboratory08/14/2018
Yes
01/25/20197 Day Break -- Specimen 2 break was outside allowable range. Correct final result is 4390 PSI.
2018-07-18-11-4ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)SD, CT HQ - Sacramento Cement Testing Laboratory09/04/2018
Yes
01/25/201928 Day Break -- Specimen 3 break was outside allowable range. Correct final result is 5320 PSI.
2018-07-18-11-5ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement MortarStephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory08/01/2018Stephen Donnelly
Yes
01/25/2019
2018-07-18-11-6ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat NeedleStephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory08/22/2018Stephen Donnelly
Yes
01/25/2019
2018-07-18-11-7ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability ApparatusStephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory09/12/2018Stephen Donnelly
Yes
01/25/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-07-18-11-2 ASTM C109-11 (Verified)
DIME Test ID: 2018-07-18-11-3 ASTM C109-11 (Verified)
DIME Test ID: 2018-07-18-11-4 ASTM C109-11 (Verified)
DIME Test ID: 2018-07-18-11-5 ASTM C185-15a (Verified)
DIME Test ID: 2018-07-18-11-6 ASTM C191-13 (Verified)
DIME Test ID: 2018-07-18-11-7 ASTM C204-11 (Verified)