Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-06-15-3

Project Information

Project IdentifiersProject ID: 212741
DEA: 020E1804
EFIS: 0200000022
DIST-CO-RTE-PM02-PLU-89-29.8/30.2
Award Date12/13/2017
Closeout Date12/17/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionPLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY
QA Service Level1 (Verified on 12/06/2017)

Sample Information

Sample Taken Date06/15/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/19/2018
Sample typeAcceptance A brief description of the samplegreen coated rebar
The quantity of what the sample constitutes5 heats 2 powder batches From where was the sample collectedFabricator
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler5624806984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Brighton CO Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-040-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)3 - 1202001236 4 - 4074535 5 - 4074245 5 - 4074328 9 - 4067634
Rebar Epoxy Batch Number(s)UE86724NA UA34962NA Rebar Coating SpecificationASTM A775
Rebar Size (#)3 4 5 9 Rebar Coating ColorGreen
Rebar ManufacturerNucor,CMC Rebar CoaterCMC Brighton CO
Rebar Powder ManufacturerAkzoNobel Surface Chemistry, LLC Release NumberNot applicable
Quality Assurance CodeNot applicable

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-06-15-3-1ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018
2018-06-15-3-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018
2018-06-15-3-3ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018#4
2018-06-15-3-4ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018#5 Rebar Heat #4074328
2018-06-15-3-5ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018
2018-06-15-3-6ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018
2018-06-15-3-7ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/20/2018Fred Saylor
Yes
07/02/2018

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-06-15-3-1 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2018-06-15-3-2 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2018-06-15-3-3 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2018-06-15-3-4 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2018-06-15-3-5 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2018-06-15-3-6 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2018-06-15-3-7 ASTM A775-07b-re14 (Verified)