Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2018-05-25-11
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
Award Date | 11/05/2015 |
Closeout Date | 01/18/2022 |
Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 05/25/2018 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/31/2018 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ahmad | Last name of sampler or witnessed by | Ankir |
Title of sampler | TE | Telephone number of sampler | Unknown |
Laboratory sample identification | 934-0525 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Roberts Lucern Valley | Transportation Laboratory (TL) Number | 0525 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | VICTORVILLE OH SEPERATION NEW AND WIDENED BRIDGE |
Structure name | VICTORVILLE OH SEPERATION NEW AND WIDENED BRIDGE |
Material Information
Material Type | Concrete | The concrete mix design number | SC675B38 |
---|---|---|---|
The truck number from where the sample was collected | 1538 | The batch plant ticket number from where the sample was collected | 13667768 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | AMES CONSTRUCTION |
A detailed description of where the material sample was collected | TRUCK DISCHARGE LOAD17 | Where the material sample would have been placed if not sampled | BENT CAP AT PIER WALL 4 WIDENED RT AND LF |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2018-05-25-11-1 ASTM C39-17a (Verified)
DIME Test ID: 2018-05-25-11-2 ASTM C39-17a (Verified)
DIME Test ID: 2018-05-25-11-3 ASTM C39-17a (Verified)