Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-04-04-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date04/04/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/05/2018
Sample typeQuality Assurance A brief description of the sampleFriction welded headed rebar
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byGary Last name of sampler or witnessed byMaComb
Title of samplerAssociate Steel Inspector Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberL1003718
Inspector Lot Number from the Transportation Laboratory (TL) FormL10-037-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)6503032702 Head Manufacturer Lot Number(s)NF15103495
Rebar Size#8 Headed Bar Model NameHRC Friction welded plate
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeRectanglar Rebar ManufacturerGerdau
Head ManufacturerNucor Head FabricatorNucor
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-04-04-1-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2018Fred
Yes
04/13/2018Bar Broke; OK Necking
2018-04-04-1-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2018Fred
Yes
04/13/2018Bar Broke; OK Necking
2018-04-04-1-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2018Fred
Yes
04/13/2018Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-04-04-1-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2018-04-04-1-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2018-04-04-1-3 ASTM A970-15e1 (Verified)