Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-03-14-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212618
DEA: 044G0564
EFIS: 0417000154
DIST-CO-RTE-PM04-ALA-680-M2.4/M12.4
Award Date11/16/2017
Closeout Date12/08/2022
Work DescriptionROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location DescriptionFREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/16/2017)

Sample Information

Sample Taken Date03/14/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/19/2018
Sample typeQuality Assurance A brief description of the sampleGreen Epoxy Dowels
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byRick Last name of sampler or witnessed byBettencourt
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) NumberC927477
Inspector Lot Number from the Transportation Laboratory (TL) FormS2502518 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat Numberunknown
Dowel Epoxy Batch NumberUnknown Dowel Coating SpecificationASTM A775
Dowel Size1.5 in Dowel Coating ColorGreen
Dowel ManufacturerUnknown Dowel CoaterDayton Superior
Release Number1402397-1 Quality Assurance CodeUnknown
Rebar Size (#)Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-03-14-2-1ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/20/2018Fred Saylor
Yes
03/27/2018
2018-03-14-2-2ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory03/20/2018Fred Saylor
Yes
03/27/2018

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-03-14-2-1 ASTM A884-14 (Verified)
DIME Test ID: 2018-03-14-2-2 ASTM A884-13 (Verified)