Owner Lab
- CT - Unassigned/General Field Laboratory
DIME Sample ID 2017-12-28-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 01/31/2017) |
Sample Information
Sample Taken Date | 12/28/2017 |
Sample Unique Key | 1 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 12/29/2017 |
Sample type | Quality Assurance |
A brief description of the sample | QA samples |
The quantity of what the sample constitutes | 12 |
From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Subramony |
Last name of sampler or witnessed by | Krishnamoorthy |
Title of sampler | QAI |
Telephone number of sampler | 9514366777 |
Laboratory sample identification | unknown |
Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar |
Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L88-047-17 |
Structure unique identifier | Not set |
Structure name | Not set |
---|
Material Information
Material Type | SMTL TM5 - Welded Hoops |
Production or Authorization Testing | Production Testing |
Service or Ultimate | Ultimate |
Rebar Heat Number(s) | 65028912-02 |
Hoop Manufacturer Lot Number(s) | 1,4 and 10 |
Material Standard Code | ASTM A706 |
Material Grade | 60 |
Rebar Size | 7 |
Diameter of Hoop | 5'-5" |
Epoxy Coated | No |
Epoxy Coating Color | NA |
Rebar Manufacturer | Gerdau |
Welding Company | TNT Rebar |
Coating Standards | Uncoated |
Weld Type | Flash Welded |
---|
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2017-12-28-1-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
2017-12-28-1-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
2017-12-28-1-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke at Weld | |
2017-12-28-1-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
2017-12-28-1-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke at Weld | |
2017-12-28-1-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
2017-12-28-1-7 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
2017-12-28-1-8 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
2017-12-28-1-9 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke at Weld | |
2017-12-28-1-10 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Brian | CT HQ - Sacramento Structural Materials Testing Laboratory | 01/03/2018 | Brian | Yes | 01/11/2018 | Bar Broke; OK Necking | |
39391393923939339394393953939639397393983939939400