Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-12-14-37

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208967
DEA: 110223U4
EFIS: 1112000102
DIST-CO-RTE-PM11-SD-5,89-R29.1/R30.5
Award Date12/18/2014
Closeout Date02/04/2022
Work DescriptionREPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT
QA Service Level1 (Verified on 01/21/2015)

Sample Information

Sample Taken Date12/14/2017 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/15/2017
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byMichael Last name of sampler or witnessed byCharak
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau Transportation Laboratory (TL) NumberC604716
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5, 6 Coupler ModelDBL BRL Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)6335, 5163 Rebar Heat Number(s)6502861303, 6502921002
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-12-14-37-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2017Fred
Yes
12/25/2017Service Splice
2017-12-14-37-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2017Fred
Yes
12/25/2017Service Splice
2017-12-14-37-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2017Fred
Yes
12/25/2017Service Splice
2017-12-14-37-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2017Fred
Yes
12/25/2017Service Splice
2017-12-14-37-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2017Fred
Yes
12/25/2017Service Splice
2017-12-14-37-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2017Fred
Yes
12/25/2017Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-12-14-37-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-14-37-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-14-37-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-14-37-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-14-37-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-14-37-6 CTM 670-December 2013 (Verified)