Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-12-01-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211794
DEA: 044G5104
EFIS: 0412000483
DIST-CO-RTE-PM04-SOL-80-31.4,32.6
Award Date01/20/2017
Closeout Date09/12/2019
Work DescriptionBRIDGE CONSTRUCTION
Location DescriptionSOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING
QA Service Level1 (Verified on 01/03/2017)

Sample Information

Sample Taken Date12/01/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/01/2017
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byM Last name of sampler or witnessed byKIM
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Dayton Transportation Laboratory (TL) NumberC967303
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler Manufacturer Dayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size11 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)74101369 Rebar Heat Number(s)4067545
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-12-01-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/04/2017Brian
Yes
12/12/2017Service Splice
2017-12-01-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/04/2017Brian
Yes
12/12/2017Service Splice
2017-12-01-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/04/2017Brian
Yes
12/12/2017Srevice Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-12-01-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-01-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-01-2-3 CTM 670-December 2013 (Verified)