Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2017-09-15-22

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date09/15/2017 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/16/2017
Sample typeQuality Control A brief description of the sample6x12 Cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byTodd Last name of sampler or witnessed byBeebout
Title of samplerQC Field Technician Telephone number of samplerUnknown
Laboratory sample identificationSet 4 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJobsite Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberG3-15-STR-002
The truck number from where the sample was collectedLoad 26 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 4
A detailed description of where the material sample was collectedBent 2A Footing Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-09-15-22-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensCody Cuevas, G3 Quality, Incorporated - Cerritos09/22/2017Nick Schaefer
Yes
11/29/2017
2017-09-15-22-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensCody Cuevas, G3 Quality, Incorporated - Cerritos10/13/2017Nick Schaefer
Yes
11/29/2017
2017-09-15-22-3ASTM C1064-12: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteTodd Beebout, G3 Quality, Incorporated - Cerritos09/15/2017Nick Schaefer
Yes
11/29/2017
2017-09-15-22-4ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteTodd Beebout, G3 Quality, Incorporated - Cerritos09/15/2017Nick Schaefer
Yes
11/29/2017
2017-09-15-22-5ASTM C173-16: Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric MethodTodd Beebout, G3 Quality, Incorporated - Cerritos09/15/2017Nick Schaefer
Yes
11/29/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-09-15-22-1 ASTM C39-17a (Verified)
DIME Test ID: 2017-09-15-22-2 ASTM C39-17a (Verified)
DIME Test ID: 2017-09-15-22-3 ASTM C1064-12 (Verified)
DIME Test ID: 2017-09-15-22-4 ASTM C143-15a (Verified)
DIME Test ID: 2017-09-15-22-5 ASTM C173-16 (Verified)