Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2017-10-31-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/31/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/31/2017
Sample typeQuality Assurance A brief description of the sampleCement
The quantity of what the sample constitutes500g From where was the sample collectedOther
First name of sampler or witnessed byTimothy Last name of sampler or witnessed byOMalley
Title of samplerTET Telephone number of samplerUnknown
Laboratory sample identificationCM179012 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility name059 Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandNevada Cement
MillFernley Type of Cementitious MaterialType II Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-10-31-4-2ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)TTO, CT HQ - Sacramento Cement Testing Laboratory11/07/2017
Yes
03/22/20197 Day Break Control -- Specimen 1 break was outside allowable range. Correct final result is 4160 PSI.
2017-10-31-4-3ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)TTO, CT HQ - Sacramento Cement Testing Laboratory11/28/2017
Yes
03/22/201928 Day Break Control -- Specimen 3 break was outside allowable range. Correct final result is 5210 PSI.