Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-10-24-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212143
DEA: 101F1604
EFIS: 1016000107
DIST-CO-RTE-PM10-MER-33,5-R16.6
Award Date05/01/2017
Closeout Date03/29/2018
Work DescriptionBRIDGE REPAIR
Location DescriptionMERCED COUNTY IN SANTA NELLA AT ROUTE 33/5 SEPARATION
QA Service Level1 (Verified on 07/20/2017)

Sample Information

Sample Taken Date10/24/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/24/2017
Sample typeQuality Assurance A brief description of the sample4, 5 couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byYe Last name of sampler or witnessed byYang
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris rebar Dayton Transportation Laboratory (TL) NumberC06001468
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size4, 5 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A150277, 74100793 Rebar Heat Number(s)SE16104201, SE16103896
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-10-24-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/2017Fred
Yes
11/02/2017Service Splice
2017-10-24-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/2017Fred
Yes
11/02/2017Service Splice
2017-10-24-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/2017Fred
Yes
11/02/2017Service Splice
2017-10-24-4-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/2017Fred
Yes
11/02/2017Service Splice
2017-10-24-4-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/2017Fred
Yes
11/02/2017Service Splice
2017-10-24-4-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/2017Fred
Yes
11/02/2017Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-10-24-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-4-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-4-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-4-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-4-6 CTM 670-December 2013 (Verified)