Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-09-25-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date09/25/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/16/2017
Sample typeQuality Assurance A brief description of the sampleHeaded Bars
The quantity of what the sample constitutes12 From where was the sample collectedManufacturer
First name of sampler or witnessed byDanny Last name of sampler or witnessed byLalonde
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarSplice Gerdau Transportation Laboratory (TL) NumberC591516
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)65026740 Head Manufacturer Lot Number(s)A144224
Rebar Size5 Headed Bar Model NameButtonhead
Size of HeadReduced Size - 4x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerGerdau
Head ManufacturerBarSplice Head FabricatorBarSplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-09-25-6-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-7ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-8ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-9ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking
2017-09-25-6-10ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2017Brian
Yes
10/30/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-09-25-6-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-6 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-7 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-8 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-9 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-10 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-11 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-09-25-6-12 ASTM A970-15e1 (Verified)