Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2017-09-08-3

Project Information

Project IdentifiersProject ID: 211778
DEA: 04235654
EFIS: 0400000680
DIST-CO-RTE-PM04-SM-101,114-1.3/2.5,5.0/5.3
Award Date02/10/2017
Closeout Date01/08/2020
Work DescriptionRECONSTRUCT INTERCHANGE
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATIONS ON ROUTE 101 FROM 0.4 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.6 MILE SOUTH OF HENDERSON UNDERPASS AND ON ROUTE 114 FROM WILLOW ROAD SEPARATION TO NEWBRIDGE STREET
QA Service Level1 (Verified on 10/24/2016)

Sample Information

Sample Taken Date09/08/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Assurance A brief description of the sampleResistance welded hoops
The quantity of what the sample constitutes324 From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC939714
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-152-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4069064
Hoop Manufacturer Lot Number(s)Lot 1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop4'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-09-08-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2017Fred
Yes
09/21/2017Bar Broke; OK Necking
2017-09-08-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2017Fred
Yes
09/21/2017Bar Broke; OK Necking
2017-09-08-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2017Fred
Yes
09/21/2017Bar Broke; OK Necking
2017-09-08-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2017Fred
Yes
09/21/2017Bar Broke; OK Necking
2017-09-08-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2017Fred
Yes
09/21/2017Bar Broke; OK Necking
2017-09-08-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/13/2017Fred
Yes
09/21/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-09-08-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-09-08-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-09-08-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-09-08-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-09-08-3-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-09-08-3-6 CTM 670-December 2013 (Verified)