Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-08-18-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208947
DEA: 060P2904
EFIS: 0612000106
COOP: 061562
DIST-CO-RTE-PM06-KER-155-1.5
Award Date03/15/2017
Closeout Date08/19/2021
Work DescriptionCONSTRUCT ROUNDABOUT AND SR 155 AND BROWING ROAD
Location DescriptionCITY OF DELANO
QA Service Level1 (Verified on 05/01/2017)

Sample Information

Sample Taken Date08/18/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/18/2017
Sample typeQuality Assurance A brief description of the sample2 bars selected at random
The quantity of what the sample constitutes31 From where was the sample collectedSource
First name of sampler or witnessed byRichard Last name of sampler or witnessed byBettencourt
Title of samplerCT METS QA INSPECTOR Telephone number of sampler209-201-5432
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Modesto Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-166-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat NumberPL17203420
Dowel Epoxy Batch Number7596024672 Dowel Coating SpecificationASTM A884
Dowel Size1.25 in Dowel Coating ColorGreen
Dowel ManufacturerNucor Dowel CoaterDayton Superior
Release Number1351031-1 Quality Assurance CodeUnknown
Rebar Size (#)Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-08-18-5-1ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/23/2017Fred Saylor
Yes
08/30/2017
2017-08-18-5-2ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/23/2017Fred Saylor
Yes
08/30/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-08-18-5-1 ASTM A884-14 (Verified)