Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-05-17-14

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date05/17/2017 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/07/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byRuss Last name of sampler or witnessed byLynch
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberC970156
Inspector Lot Number from the Transportation Laboratory (TL) FormL9607517 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)65026003
Hoop Manufacturer Lot Number(s)1, 14 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-10" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerRKR Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-05-17-14-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/2017Brian
Yes
06/15/2017Bar Broke; OK Necking
2017-05-17-14-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/2017Brian
Yes
06/15/2017Bar Broke; OK Necking
2017-05-17-14-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/2017Brian
Yes
06/15/2017Bar Broke; OK Necking
2017-05-17-14-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/2017Brian
Yes
06/15/2017Bar Broke; OK Necking
2017-05-17-14-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/2017Brian
Yes
06/15/2017Bar Broke; OK Necking
2017-05-17-14-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/2017Brian
Yes
06/15/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-17-14-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-17-14-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-17-14-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-17-14-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-17-14-5 CTM 670-December 2013 (Verified)