Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2017-05-25-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211237
DEA: 080Q7904
EFIS: 0800020481
DIST-CO-RTE-PM08-SBD-40-R93.1/94.2
Award Date06/03/2016
Closeout Date05/03/2018
Work DescriptionREPLACE HOFF WASH BRIDGE (BRIDGE NUMBER 54-0889L/R)
Location DescriptionSAN BERNARDINO COUNTY FROM 0.3 MILE WEST TO 0.4 MILE EAST OF HOFF WASH BRIDGE
QA Service Level1 (Verified on 07/01/2016)

Sample Information

Sample Taken Date05/25/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2017
Sample typeQuality Assurance A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed bySUNNY Last name of sampler or witnessed byYANG
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification953-525 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCEMEX Transportation Laboratory (TL) Number20170525
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameABUTMENT 3 AND WING WALLS

Material Information

Material TypeConcrete The concrete mix design number1592266
The truck number from where the sample was collected5780 The batch plant ticket number from where the sample was collected44464599
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 9 Where the material sample would have been placed if not sampledabutment 3 and wing walls
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-05-25-4-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/01/2017Matthew Clayton
Yes
06/01/2017
2017-05-25-4-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/22/2017Matthew Clayton
Yes
06/23/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-25-4-1 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-25-4-2 ASTM C39-17a (Verified)